The -5℃ air-cooled screw chiller is an industrial refrigeration equipment that dissipates heat through an air-cooled method, adopts a screw compressor, and can stably output low-temperature chilled water at -5℃.
Item No :
BSL-100ASEMOrder(MOQ) :
1Payment :
EXW/FOB/CIF/FCA/DPU/DDUProduct Origin :
CHINAColor :
CustomizableShipping Port :
SHANGHAI/NANJINGLead Time :
20Weight :
1950KG
Its core working unit consists of four parts, which work together to realize the refrigeration cycle.
Screw Compressor: Known as the "heart" of the equipment, it compresses the refrigerant through the meshing of twin screws to provide continuous and stable refrigeration power. It features high efficiency, low noise, and a long service life.
Air-Cooled Condenser: It dissipates the heat carried by the refrigerant into the air through forced ventilation via fans. It does not require a cooling tower, which simplifies the installation conditions.
Evaporator: It conducts heat exchange with the water to be cooled (refrigerant carrier), lowers the water temperature to -5℃, and then delivers the chilled water to the equipment that needs cooling.
Control System: Adopting PLC (Programmable Logic Controller) or microcomputer control, it can accurately adjust the outlet water temperature, monitor the equipment operation status, and realize automatic start-stop and fault alarm functions.
Safety Protection Function
Key Components
Twin-screw compressor, equipped with high-efficiency heat exchangers (evaporator, condenser).
Control System
PLC intelligent control, supporting temperature setting, operation monitoring, and fault alarm functions.
Auxiliary Components
Dry filter, expansion valve, oil separator, etc., which ensure the stable operation of the system.
FAQ
Q1: What is the working principle of the -5℃ air-cooled screw chiller?
A1: The working principle of the air-cooled screw chiller is as follows: The gaseous refrigerant discharged from the evaporator is adiabatically compressed by the compressor into a high-temperature and high-pressure state. It then enters the condenser, where it is cooled and condensed into a liquid refrigerant at constant pressure. After that, the liquid refrigerant passes through the throttle valve, expands to a low-pressure state, and becomes a gas-liquid mixture. The low-temperature and low-pressure liquid refrigerant absorbs heat from the substance to be cooled in the evaporator, turns back into gaseous refrigerant, and then re-enters the compressor through the pipeline to start a new cycle.
Q2: What applications is this chiller suitable for?
A2:A: It is widely used in scenarios requiring large-scale refrigeration, covering both civil and industrial fields.
Q3: What are the characteristics of the -5℃ air-cooled screw chiller?
A3: It usually has the following characteristics:
Model And Technical Parameter
| Model | Unit | 100ASEM | 140ASEM | 180ASEM | 200ASEM | 230ASEM | 260ASEM |
| Temp. control range | Inlet water temperature -5-25℃ | ||||||
| Temp. accuracy | PID±1℃ | ||||||
| Power | AC3Φ380V 50HZ 3P+E(5M) | ||||||
| Heat transfer medium | Water | ||||||
| Cooling methad | Indirect cooling | ||||||
| Refrigeration capacity | KW | 48 | 65 | 85 | 93 | 115 | 125 |
| Pump power | HP | 35 | 45 | 60 | 70 | 80 | 90 |
| Max.pump flow | L/min | 95 | 165 | 236 | 315 | 385 | 415 |
| Max.pump pressure | Bar | 2 | 2.2 | 2.4 | 2.6 | 2.8 | 3 |
| Condenser(Air Volume) | m³/h | 39000 | 45000 | 57000 | 64800 | 76000 | 93000 |
| Evaporator(Water Flow) | m³/h | 12 | 16 | 22 | 25 | 30 | 33 |
| Single Fan Power | KW | 0.42 | 0.55 | 0.8 | 0.85 | 0.8 | 1.1 |
| Dimension(mm) | L | 2500 | 3000 | 3300 | 3000 | 3000 | 3000 |
| W | 1200 | 1300 | 1300 | 1800 | 2000 | 2300 | |
| H | 2250 | 2250 | 2450 | 2350 | 2300 | 2300 | |
| Weight | kg | 1820 | 2000 | 2200 | 2450 | 2600 | 2800 |
Remarks:
1.The table cooling conditions:chilled water inlet temperature 12℃,the outlet temperature 7℃,air temperature 35℃;
2.Power Supoly:3P-380V-50Hz,allowing voltage fluctuation ±10%,Allow the voltage difference ±2%;
3.The above data refer to refrigerant R22,if you need refrigerant R407 or other refrigerants,please contract;
4.Specification parameters and dimensions are subject to change due to product improvement without notice.
000
Process Flow Diagram

Application Case
Our air cooled screw is widely used across various industrial applications, including casting moulds, rubber vulcanization, wheel temperature control, hot press technology, carbon fiber production, and chemical reactions. It ensures precise temperature management, improving production efficiency and product quality in these processes.
Our Partner

Customized Solutions for Your Business, Contact Us Quickly!
Leave A Message
Scan to Wechat/Whatsapp :