A 7℃ water-cooled screw chiller is an industrial refrigeration equipment that takes a screw compressor as its core, uses water as the cooling medium, and focuses on outputting 7℃ chilled water.
Item No :
BSL-100WSEOrder(MOQ) :
1Payment :
EXW/FOB/CIF/FCA/DPU/DDUProduct Origin :
CHINAColor :
CustomizableShipping Port :
SHANGHAI/NANJINGLead Time :
22Weight :
900KG
High refrigeration efficiency: The screw compressor adopts the positive displacement compression principle, featuring stable compression ratio, which makes it suitable for medium and large-scale refrigeration needs.
Precise temperature control: It can stably maintain an outlet water temperature of 7℃, meeting the constant temperature requirements of scenarios such as precision industrial production and food processing.
Stable and reliable operation: The screw compressor has a simple structure, few wearing parts, long continuous operation time, and low maintenance costs.
Strong cooling effect: It relies on a water-cooling system (equipped with a cooling tower) for heat dissipation. Its heat dissipation efficiency is higher than that of air-cooled types, making it suitable for use in high-temperature and high-humidity environments.
Safety Protection Function
High Cooling Capacity
The structural characteristics of the screw compressor make it suitable for high cooling capacity requirements. A single unit has a wide cooling capacity range (usually several tens to several hundreds of kilowatts).
High Energy Efficiency
The operating efficiency of the screw compressor is superior to that of the reciprocating (piston) compressor. Combined with the high efficiency of water-cooled heat dissipation, the overall energy consumption is relatively low.
Stable Temperature
It can accurately control the temperature of the chilled water at around 7℃ with a small fluctuation range, meeting the process requirements for temperature precision.
Stable Operation
The screw compressor has fewer components, minimal wear, and a low failure rate, making it suitable for long-term continuous operation.
FAQ
Q1:What is the correct startup sequence for the chiller unit?
A1:Start the cooling tower fan and cooling water pump;Start the chilled water pump, and wait until the pipeline pressure stabilizes (usually ≥0.2MPa);Start the main chiller unit;After operation, observe for 3-5 minutes, and only put it into full-load operation after confirming that all parameters are normal.
Q2: What situations require an emergency shutdown during the operation of the chiller unit?
A2:The compressor produces abnormal noise, violent vibration, or the outer casing overheats (oil temperature ≥95℃);Abnormal refrigerant pressure (suction pressure ≤0.2MPa or ≥0.8MPa, discharge pressure ≥2.0MPa);ripping, smoking, or a burning smell in the electrical system;Severe leakage in the pipelines;A sudden drop in chilled water/cooling water flow (flow switch alarm is triggered).
Q3:How to adjust the cooling capacity of the chiller unit?
A3:Automatic adjustment: The unit is equipped with a PLC control system, which can automatically adjust the compressor loading/unloading according to the return water temperature of the chilled water to achieve stepless adjustment of cooling capacity;Manual adjustment: If a fixed cooling capacity is required, the target temperature can be set through the control panel, or the compressor loading ratio can be adjusted manually (it is recommended to keep it within the range of 10%-100%);Note: Frequent startup and shutdown should be avoided. After each shutdown, an interval of more than 3 minutes is required before restarting to protect the compressor.
Model And Technical Parameter
| Model | Unit | 100WSE | 140WSE | 180WSE | 200WSE | 230WSE | 260WSE |
| Temp. control range | Inlet water temperature 7-25℃ | ||||||
| Temp. accuracy | PID±1℃ | ||||||
| Power | AC3Φ380V 50HZ 3P+E(5M) | ||||||
| Heat transfer medium | Water | ||||||
| Cooling methad | Indirect cooling | ||||||
| Refrigeration capacity | KW | 98.4 | 134.1 | 176 | 196.8 | 233.6 | 256.4 |
| Pump power | HP | 35 | 45 | 60 | 70 | 80 | 90 |
| Max.pump flow | L/min | 95 | 165 | 236 | 315 | 385 | 415 |
| Max.pump pressure | Bar | 2 | 2.2 | 2.4 | 2.6 | 2.8 | 3 |
| Condenser(Water Flow) | m³/h | 22 | 29 | 38 | 43 | 51 | 56 |
| Evaporator(Water Flow) | m³/h | 17 | 24 | 31 | 34 | 41 | 45 |
| Tank Volume | L | 25 | 25 | 55 | 75 | 120 | 150 |
| Dimension(mm) | L | 900 | 900 | 900 | 900 | 900 | 900 |
| W | 1365 | 1385 | 1540 | 1665 | 1665 | 1665 | |
| H | 850 | 1050 | 1350 | 1430 | 1430 | 1670 | |
| Weight | kg | 900 | 1100 | 1400 | 1480 | 1560 | 1790 |
Remarks:
1.The table cooling conditions:chilled water inlet temperature 12℃,the outlet temperature 7℃,air temperature 35℃;
2.Power Supoly:3P-380V-50Hz,allowing voltage fluctuation ±10%,Allow the voltage difference ±2%;
3.The above data refer to refrigerant R22,if you need refrigerant R407 or other refrigerants,please contract;
4.Specification parameters and dimensions are subject to change due to product improvement without notice.
Process Flow Diagram

Application Case
Our Water cooled screw chiller is widely used across various industrial applications, including casting moulds, rubber vulcanization, wheel temperature control, hot press technology, carbon fiber production, and chemical reactions. It ensures precise temperature management, improving production efficiency and product quality in these processes.